Defect: Asymmetric covers | Pencil box
Cause: each cover is sewed separately without alignment.
Solution: Implement a mold for 2 covers during sewing to ensure consistent placement.
Typical: * * * * *
Rework difficulty: * * * * *
Rework collateral risk: * * * * *